DNB Chandler facility is operating in 23,000 sq. ft building. The facility has 20’ x 23’ chambers meeting the attenuation requirements of MIL-STD-461 and RTCA DO-160.

Also, the building has one 29’ x 23’ mode tuned chamber (MTC) that will be used for susceptibility testing. We designed the MTC for 100W amplifiers to reach 200 V/m. The chamber has 200 – 400 W amplifiers capable of reaching 200 V/m using spot-on illumination from 100 MHz – 18 GHz and able to reach field Strength level up to 6,000 V/m.

We have also partnered with another local lab to offer environmental testing:

  • Vibration
  • Thermal
  • Acceleration up to 30,000 G's
  • Sand & Dust
  • Explosive decompression
  • Explosive atmosphere
  • Hydraulic testing
  • Thermal vacuum
  • Altitude testing
  • Fluid susceptibility
  • Drop shock test

     This facility is NVLAP accredited